Buying Guide: 400-600 cu ft - Mini Split 3000S

Light grey is within entire 1800 series capacity, medium grey is 1800QT / 1800XT / 1800XTS Capacity, light blue 1800XT / 1800XTS, dark grey 1800XTS

CellarPro Cooling Systems Mini-Split 3000S Wine Cellar Refrigeration System

55°F Cooling Capacity1

Low Fan Speed
BTUH 2144   Decibels 51

Medium Fan Speed
BTUH 2398   Decibels 55

High Fan Speed
BTUH 2491   Decibels 63

Cellar Size1

  Ambient
Temperature
  Thermal Load (BTUH)
R12   R19   R30

400

Cubic Feet

70°F 1810   1676   1596
75°F 1921 1744 1636
80°F 2033 1811 1676
85°F 2144 1879 1717
90°F 2256 1946 1758
95°F 2369 2015 1800
Divider      

500

Cubic Feet

70°F 2111 1958 1867
75°F 2238 2035 1913
80°F 2366 2112 1958
85°F 2190 2006
90°F 2267 2052
95°F 2345 2100
Divider      

600

Cubic Feet

70°F 2359 2192 2092
75°F 2278 2143
80°F 2362 2194
85°F 2446 2244
90°F 2296
95°F 2347
 

CellarPro Cooling Systems Mini-Split 3000S Wine Cellar Refrigeration System

60°F Cooling Capacity1

Low Fan Speed
BTUH 2303   Decibels 51

Medium Fan Speed
BTUH 2594   Decibels 55

High Fan Speed
BTUH 3671   Decibels 63

 

Cellar Size1

  Ambient
Temperature
  Thermal Load (BTUH)
R12   R19   R30

400

Cubic Feet

70°F 1593   1475   1404
75°F 1690 1535 1440
80°F 1789 1594 1475
85°F 1888 1654 1511
90°F 1985 1712 1547
95°F 2085 1773 1584
Divider      

500

Cubic Feet

70°F 1858 1723 1643
75°F 1969 1791 1683
80°F 2082 1859 1723
85°F 2196 1927 1765
90°F 2307 1995 1806
95°F 2420 2064 1848
Divider      

600

Cubic Feet

70°F 2076 1929 1841
75°F 2200 2005 1886
80°F 2322 2079 1931
85°F 2446 2152 1975
90°F 2570 2227 2020
95°F 2671 2302 2065
Divider      

700

Cubic Feet

70°F 2314 2156 2059
75°F 2448 2237 2108
80°F 2582 2318 2158
85°F 2398 2205
90°F 2480 2255
95°F 2561 2303

The upper table shows how the CellarPro mini-split 3000S refrigeration unit will work at maintaining 55°F, the lower table at maintaining 60°F inside the wine cellar using various fan speeds and under different thermal loads. The thermal loads are derived from assumptions about the size of the cellar; the R-value in the six cellar surfaces (ie walls, floor and ceiling) and the ambient temperature outside the cellar. CellarPro mini-split 3000S refrigeration units are designed to maintain optimal wine storage temperatures in wine cellars with adequate insulation, and can be operated with the condenser exposed to conditions up to 110°F.

For more information, click on the 3000S mini-split performance and test data.

(1) The thermal loads above are calculated based on the R-Values shown for all walls and ceiling, and a concrete floor. Lower R-Values in the cellar (eg from glass doors) will increase the thermal load on the wine cellar and will require the cooling unit to operate at higher fan speeds. Warmer climates require higher insulation to enable the cooling unit to operate at lower fan speeds. To be certain that the thermal load won't exceed the capacity of the cooling unit, email your wine cellar specifications to us and we'll be glad to assist you.