Information Center > Cooling Unit Buying Guide > 

Buying Guide: 14-42 cu meters / 220V


CellarPro Cooling Systems - 4200 220V / 50Hz Cooling Unit
Cooling Capacity @ 15°C

4200VSi 220V - Low Fan Speed

BTUH: 3463    Decibels: 54

4200VSi 220V - Medium Fan Speed

BTUH: 3818     Decibels: 59

4200VSi 220V - High Fan Speed

BTUH: 4104     Decibels: 67

Cellar Insulation - Walls, Ceiling & Floor (1)
R12
R19
R30
Cellar Size
Ambient Temperature
Thermal Load BTUH
 
21°C
1858 1723 1643
 
24°C
1969 1791 1683
14 Cubic Meters
27°C
2082 1859 1723
 
29°C
2196 1927 1765
 
32°C
2307 1995 1806
 
35°C
2420 2064 1848
 
 
21°C
2465 2302 2203
 
24°C
2602 2385 2253
21 Cubic Meters
27°C
2739 2467 2302
 
29°C
2877 2550 2351
 
32°C
3014 2634 2402
 
35°C
3152 2717 2453
 
 
21°C
2988 2799 2686
 
24°C
3147 2895 2744
28 Cubic Meters
27°C
3304 2990 2800
 
29°C
3463 3087 2858
 
32°C
3622 3183 2916
 
35°C
3780 3279 2974
 
 
21°C
3509 3300 3173
 
24°C
3685 3406 3238
35 Cubic Meters
27°C
3861 3512 3301
 
29°C
4037 3619 3365
 
32°C
X 3727 3431
 
35°C
X 3833 3495
 
 
21°C
4055 3824 3685
 
24°C
X 3942 3756
42 Cubic Meters
27°C
X 4059 3827
 
29°C
X 4176 3898
 
32°C
X X 3969
 
35°C
X X 4040

Legend
The table is shaded to show how the 4200 cooling unit will work at 15°C in a 220V / 50Hz environment using various fan speeds under various thermal loads. The thermal loads are derived from assumptions about the size of the cellar; the R-value in the six cellar surfaces (ie walls, floor and ceiling) and the ambient temperature outside the cellar, as follows:

  • The light-shaded numbers represent thermal loads that are within the capacity of the cooling unit at the low fan speed
  • The medium-shaded numbers represent thermal loads that are within the capacity of the cooling unit at the medium fan speed
  • The dark-shaded numbers represent thermal loads that are within the capacity of the cooling unit at the high fan speed
  • "X" indicates conditions that are beyond the capacity of our 4200 Series cooling units

Summary
In 220V / 50Hz environments, CellarPro 4200 wine cooling units are designed to maintain 15°F temperatures in wine cellars up to 28 cubic meters with adequate insulation, and can be operated with the condenser exposed to conditions up to 46°C. For more information, click on our 4200VS performance and test data.

Please note:   The thermal loads above are calculated based on the R-Values shown for all walls and ceiling, and a concrete floor.  Lower R-Values in the cellar (eg from glass doors) will increase the thermal load on the wine cellar and will require the cooling unit to operate at higher fan speeds. Warmer climates require higher insulation to enable the cooling unit to operate at lower fan speeds. To be certain that the thermal load won't exceed the capacity of the cooling unit, email your wine cellar specifications to us and we'll be glad to assist you.