Buying Guide: 1750-2000 cu ft - 8000S
CellarPro Wine Cellar Refrigeration - 8000S Split Systems Cooling Capacity @ 55°F (1)
|
8000S - Low Fan Speed |
BTUH: 5961 Decibels: 54 |
|
8000S - Medium Fan Speed |
BTUH: 6346 Decibels: 58 |
|
8000S - High Fan Speed |
BTUH: 6713 Decibels: 66 |
| Cellar Insulation - Walls, Ceiling & Floor (1) |
R12 |
R19 |
R30 |
| Cellar Size |
Ambient Temperature |
Thermal Load BTUH |
| |
70°F |
5141 |
4860 |
4691 |
| |
75°F |
5376 |
5002 |
4775 |
| 1750 Cubic Feet |
80°F |
5612 |
5144 |
4861 |
| |
85°F |
5849 |
5288 |
4949 |
| |
90°F |
6085 |
5431 |
5035 |
| |
95°F |
6324 |
5576 |
5124 |
| |
| |
70°F |
5861 |
5556 |
5372 |
| |
75°F |
6116 |
5711 |
5466 |
| 2000 Cubic Feet |
80°F |
6373 |
5866 |
5558 |
| |
85°F |
6630 |
6022 |
5653 |
| |
90°F |
X (6888) |
6178 |
5748 |
| |
95°F |
X (7146) |
6335 |
5844 |
Cooling Capacity @ 60°F (1)
|
8000S - Low Fan Speed |
BTUH: 6392 Decibels: 54 |
|
8000S - Medium Fan Speed |
BTUH: 6765 Decibels: 58 |
|
8000S - High Fan Speed |
BTUH: 7183 Decibels: 66 |
| Cellar Insulation - Walls, Ceiling & Floor (1) |
R12 |
R19 |
R30 |
| Cellar Size |
Ambient Temperature |
Thermal Load BTUH |
| |
70°F |
4524 |
4277 |
4128 |
| |
75°F |
4731 |
4402 |
4202 |
| 1750 Cubic Feet |
80°F |
4939 |
4527 |
4278 |
| |
85°F |
5147 |
4653 |
4355 |
| |
90°F |
5355 |
4779 |
4431 |
| |
95°F |
5565 |
4907 |
4509 |
| |
| |
70°F |
5158 |
4889 |
4727 |
| |
75°F |
5382 |
5026 |
4810 |
| 2000 Cubic Feet |
80°F |
5608 |
5162 |
4891 |
| |
85°F |
5834 |
5299 |
4975 |
| |
90°F |
6061 |
5437 |
5058 |
| |
95°F |
6288 |
5575 |
5143 |
Legend The upper table is shaded to show how the 8000S cooling unit will work at maintaining 55°F, and the lower table is shaded to show how the 8000S cooling unit will work at maintaining 60°F, inside the wine cellar using various fan speeds under various thermal loads. The thermal loads are derived from assumptions about the size of the cellar; the R-value in the six cellar surfaces (ie walls, floor and ceiling) and the ambient temperature outside the cellar, as follows:
- The light-shaded numbers represent thermal loads that are within the capacity of the cooling unit at the low fan speed
- The medium-shaded numbers represent thermal loads that are within the capacity of the cooling unit at the medium fan speed
- The dark-shaded numbers represent thermal loads that are within the capacity of the cooling unit at the high fan speed
- "X" indicates conditions that are beyond the capacity of our 8000S Series cooling units
Summary CellarPro 8000S wine cooling units are designed to maintain optimal wine storage temperatures in wine cellars up to 2250 cubic feet with adequate insulation, and can be operated with the condenser exposed to conditions up to 110°F. For more information, click on our 8000S performance and test data.
Please note: The thermal loads above are calculated based on the R-Values shown for all walls and ceiling, and a concrete floor. Lower R-Values in the cellar (eg from glass doors) will increase the thermal load on the wine cellar and will require the cooling unit to operate at higher fan speeds. Warmer climates require higher insulation to enable the cooling unit to operate at lower fan speeds. To be certain that the thermal load won't exceed the capacity of the cooling unit, email your wine cellar specifications to us and we'll be glad to assist you.
|
|
|
|