Buying Guide: 400-600 cu ft - Mini Split 3000S
CellarPro Cooling Systems - Mini-Split 3000S Wine Cellar Refrigeration System Cooling Capacity @ 55°F (1)
|
3000S - Low Fan Speed |
BTUH: 2144 Decibels: 51 |
|
3000S - Medium Fan Speed |
BTUH: 2398 Decibels: 55 |
|
3000S - High Fan Speed |
BTUH: 2491 Decibels: 63 |
| Cellar Insulation - Walls, Ceiling & Floor (1) |
R12 |
R19 |
R30 |
| Cellar Size |
Ambient Temperature |
Thermal Load (BTUH) |
| |
70°F |
1810 |
1676 |
1596 |
| |
75°F |
1921 |
1744 |
1636 |
| 400 Cubic Feet |
80°F |
2033 |
1811 |
1676 |
| |
85°F |
2144 |
1879 |
1717 |
| |
90°F |
2256 |
1946 |
1758 |
| |
95°F |
2369 |
2015 |
1800 |
| |
| |
70°F |
2111 |
1958 |
1867 |
| |
75°F |
2238 |
2035 |
1913 |
| 500 Cubic Feet |
80°F |
2366 |
2112 |
1958 |
| |
85°F |
X |
2190 |
2006 |
| |
90°F |
X |
2267 |
2052 |
| |
95°F |
X |
2345 |
2100 |
| |
| |
70°F |
2359 |
2192 |
2092 |
| |
75°F |
X |
2278 |
2143 |
| 600 Cubic Feet |
80°F |
X |
2362 |
2194 |
| |
85°F |
X |
2446 |
2244 |
| |
90°F |
X |
X |
2296 |
| |
95°F |
X |
X |
2347 |
Cooling Capacity @ 60°F (1)
|
3000S - Low Fan Speed |
BTUH: 2303 Decibels: 51 |
|
3000S - Medium Fan Speed |
BTUH: 2594 Decibels: 55 |
|
3000S - High Fan Speed |
BTUH: 2671 Decibels: 63 |
| Cellar Insulation - Walls, Ceiling & Floor (1) |
R12 |
R19 |
R30 |
| Cellar Size |
Ambient Temperature |
Thermal Load BTUH |
| |
70°F |
1593 |
1475 |
1404 |
| |
75°F |
1690 |
1535 |
1440 |
| 400 Cubic Feet |
80°F |
1789 |
1594 |
1475 |
| |
85°F |
1888 |
1654 |
1511 |
| |
90°F |
1985 |
1712 |
1547 |
| |
95°F |
2085 |
1773 |
1584 |
| |
| |
70°F |
1858 |
1723 |
1643 |
| |
75°F |
1969 |
1791 |
1683 |
| 500 Cubic Feet |
80°F |
2082 |
1859 |
1723 |
| |
85°F |
2196 |
1927 |
1765 |
| |
90°F |
2307 |
1995 |
1806 |
| |
95°F |
2420 |
2064 |
1848 |
| |
| |
70°F |
2076 |
1929 |
1841 |
| |
75°F |
2200 |
2005 |
1886 |
| 600 Cubic Feet |
80°F |
2322 |
2079 |
1931 |
| |
85°F |
2446 |
2152 |
1975 |
| |
90°F |
2570 |
2227 |
2020 |
| |
95°F |
2671 |
2302 |
2065 |
| |
| |
70°F |
2314 |
2156 |
2059 |
| |
75°F |
2448 |
2237 |
2108 |
| 700 Cubic Feet |
80°F |
2582 |
2318 |
2158 |
| |
85°F |
X |
2398 |
2205 |
| |
90°F |
X |
2480 |
2255 |
| |
95°F |
X |
2561 |
2303 |
Legend The top table is shaded to show how our mini-split 3000S wine cellar refrigeration system will work at maintaining 55°F inside the wine cellar, and the bottom table is shaded to show how our mini-split 3000S will work at maintaining 60°F inside the wine cellar, using various fan speeds under various thermal loads. The thermal loads are derived from assumptions about the size of the cellar; the R-value in the six cellar surfaces (ie walls, floor and ceiling) and the ambient temperature outside the cellar, as follows:
- The light-shaded numbers represent thermal loads that are within the capacity of the cooling unit at the low fan speed
- The medium-shaded numbers represent thermal loads that are within the capacity of the cooling unit at the medium fan speed
- The dark-shaded numbers represent thermal loads that are within the capacity of the cooling unit at the high fan speed
- "X" indicates conditions that are beyond the capacity of our 3000S split refrigeration system
Summary CellarPro mini-split refrigeration systems are designed to maintain optimal wine storage temperatures in wine cellars with adequate insulation, and the condenser is designed to handle temperatures up to 110°F. For more information, click on our 3000S mini-split performance and test data.
Please note: The thermal loads above are calculated based on the R-Values shown for all walls and ceiling, and a concrete floor. Lower R-Values in the cellar (eg from glass doors) will increase the thermal load on the wine cellar and will require the cooling unit to operate at higher fan speeds. Warmer climates require higher insulation to enable the cooling unit to operate at lower fan speeds. To be certain that the thermal load won't exceed the capacity of the cooling unit, email your wine cellar specifications to us and we'll be glad to assist you.
(1) For reference purposes, the calculated BTUH at 55°F for WhisperKool Platinum Mini is 1465 and the calculated BTUH at 60°F is 1590.
|
|
|
|