Buying Guide: 400-800 cu ft - 3200VS
CellarPro Cooling Systems - 3200 Series Cooling Units Cooling Capacity @ 55°F (1)
|
3200VSi - Low Fan Speed |
BTUH: 2487 Decibels: 54 |
|
3200VSi - Medium Fan Speed |
BTUH: 2876 Decibels: 58 |
|
3200VSi - High Fan Speed |
BTUH: 3040 Decibels: 66 |
| Cellar Insulation - Walls, Ceiling & Floor (1) |
R12 |
R19 |
R30 |
| Cellar Size |
Ambient Temperature |
Thermal Load (BTUH) |
| |
70°F |
1810 |
1676 |
1596 |
| |
75°F |
1921 |
1744 |
1636 |
| 400 Cubic Feet |
80°F |
2033 |
1811 |
1676 |
| |
85°F |
2146 |
1879 |
1717 |
| |
90°F |
2256 |
1946 |
1758 |
| |
95°F |
2369 |
2015 |
1800 |
| |
| |
70°F |
2111 |
1958 |
1867 |
| |
75°F |
2238 |
2035 |
1913 |
| 500 Cubic Feet |
80°F |
2366 |
2112 |
1958 |
| |
85°F |
2495 |
2190 |
2006 |
| |
90°F |
2622 |
2267 |
2052 |
| |
95°F |
2750 |
2345 |
2100 |
| |
| |
70°F |
2359 |
2192 |
2092 |
| |
75°F |
2500 |
2278 |
2143 |
| 600 Cubic Feet |
80°F |
2639 |
2362 |
2194 |
| |
85°F |
2779 |
2446 |
2244 |
| |
90°F |
2920 |
2531 |
2296 |
| |
95°F |
3040 |
2616 |
2347 |
| |
| |
70°F |
2630 |
2450 |
2340 |
| |
75°F |
2782 |
2542 |
2395 |
| 700 Cubic Feet |
80°F |
2934 |
2634 |
2452 |
| |
85°F |
X |
2725 |
2506 |
| |
90°F |
X |
2818 |
2562 |
| |
95°F |
X |
2910 |
2617 |
| |
| |
70°F |
2902 |
2711 |
2596 |
| |
75°F |
3040 |
2807 |
2653 |
| 800 Cubic Feet |
80°F |
X |
2904 |
2712 |
| |
85°F |
X |
3001 |
2771 |
| |
90°F |
X |
X |
2828 |
| |
95°F |
X |
X |
2887 |
Cooling Capacity @ 60°F (1)
|
3200VSi - Low Fan Speed |
BTUH: 2663 Decibels: 54 |
|
3200VSi - Medium Fan Speed |
BTUH: 3084 Decibels: 58 |
|
3200VSi - High Fan Speed |
BTUH: 3258 Decibels: 66 |
| Cellar Insulation - Walls, Ceiling & Floor (1) |
R12 |
R19 |
R30 |
| Cellar Size |
Ambient Temperature |
Thermal Load BTUH |
| |
70°F |
1593 |
1475 |
1404 |
| |
75°F |
1690 |
1535 |
1440 |
| 400 Cubic Feet |
80°F |
1789 |
1594 |
1475 |
| |
85°F |
1888 |
1654 |
1511 |
| |
90°F |
1985 |
1712 |
1547 |
| |
95°F |
2085 |
1773 |
1584 |
| |
| |
70°F |
1858 |
1723 |
1643 |
| |
75°F |
1969 |
1791 |
1683 |
| 500 Cubic Feet |
80°F |
2082 |
1859 |
1723 |
| |
85°F |
2196 |
1927 |
1765 |
| |
90°F |
2307 |
1995 |
1806 |
| |
95°F |
2420 |
2064 |
1848 |
| |
| |
70°F |
2076 |
1929 |
1841 |
| |
75°F |
2200 |
2005 |
1886 |
| 600 Cubic Feet |
80°F |
2322 |
2079 |
1931 |
| |
85°F |
2446 |
2152 |
1975 |
| |
90°F |
2570 |
2227 |
2020 |
| |
95°F |
2693 |
2302 |
2065 |
| |
| |
70°F |
2314 |
2156 |
2059 |
| |
75°F |
2448 |
2237 |
2108 |
| 700 Cubic Feet |
80°F |
2582 |
2318 |
2158 |
| |
85°F |
2716 |
2398 |
2205 |
| |
90°F |
2850 |
2480 |
2255 |
| |
95°F |
2984 |
2561 |
2303 |
| |
| |
70°F |
2554 |
2386 |
2284 |
| |
75°F |
2694 |
2470 |
2335 |
| 800 Cubic Feet |
80°F |
2834 |
2556 |
2387 |
| |
85°F |
2976 |
2641 |
2438 |
| |
90°F |
3116 |
2725 |
2489 |
| |
95°F |
3258 |
2811 |
2541 |
Legend
The upper table is shaded to show how the 3200VS cooling unit will work at maintaining 55°F inside the wine cellar, and the lower table is shaded to show how the 3200VS cooling unit will work at maintaining 60°F inside the wine cellar, using various fan speeds under various thermal loads. The thermal loads are derived from assumptions about the size of the cellar; the R-value in the six cellar surfaces (ie walls, floor and ceiling) and the ambient temperature outside the cellar, as follows:
- The light-shaded numbers represent thermal loads that are within the capacity of the cooling unit at the low fan speed
- The medium-shaded numbers represent thermal loads that are within the capacity of the cooling unit at the medium fan speed
- The dark-shaded numbers represent thermal loads that are within the capacity of the cooling unit at the high fan speed
- "X" indicates conditions that are beyond the capacity of our 3200 Series cooling units
Summary
CellarPro 3200 wine cooling units are designed to maintain optimal wine storage temperatures in wine cellars up to 800 cubic feet with adequate insulation, and can be operated with the condenser exposed to conditions up to 115°F. For more information, click on our 3200VS performance and test data.
Please note: The thermal loads above are calculated based on the R-Values shown for all walls and ceiling, and a concrete floor. Lower R-Values in the cellar (eg from glass doors) will increase the thermal load on the wine cellar and will require the cooling unit to operate at higher fan speeds. Warmer climates require higher insulation to enable the cooling unit to operate at lower fan speeds. To be certain that the thermal load won't exceed the capacity of the cooling unit, email your wine cellar specifications to us and we'll be glad to assist you.
(1) For reference purposes, the calculated BTUH for WhisperKool XLT 3000 is 2500 at 55°F and 2700 at 60°F.
|
|
|
|