4200VS-ECX: Sizing Table - Wine Cellars 750-1250 cubic ft

55°F Cooling Capacity(1)

Cooling Unit Output

Low Fan Speed
3282 BTUH
Decibels 54

Medium Fan Speed
3617 BTUH
Decibels 59

High Fan Speed
3938 BTUH
Decibels 67

Cellar Size

Ambient
Temperature
Thermal Load (BTUH)
R12R19R30

750

Cubic Feet

70°F280126162503
75°F295727102560
80°F311228032616
85°F326928982672
90°F342529932730
95°F358230882788

1000

Cubic Feet

70°F339531813052
75°F357632823118
80°F375533983182
85°F393535083248
90°F36173314
95°F37263380

1250

Cubic Feet

70°F37503606
75°F38713679
80°F3751
85°F3824
90°F3899
95°F

60°F Cooling Capacity(1)

Cooling Unit Output

Low Fan Speed
3597 BTUH
Decibels 54

Medium Fan Speed
3969 BTUH
Decibels 59

High Fan Speed
4267 BTUH
Decibels 67

Cellar Size

Ambient
Temperature
Thermal Load (BTUH)
R12R19R30

750

Cubic Feet

70°F246523022203
75°F260223852253
80°F273924672302
85°F287725502351
90°F301426342402
95°F315227172453

1000

Cubic Feet

70°F298827992686
75°F314728952744
80°F330429902800
85°F346330872858
90°F362231832916
95°F378032792974

1250

Cubic Feet

70°F350933003173
75°F368534063238
80°F386135123301
85°F403736193365
90°F421437273431
95°F38333495

1500

Cubic Feet

70°F405538243685
75°F425039423756
80°F40593827
85°F41763898
90°F42673969
95°F4040

The upper table shows how the 4200VS cooling unit will work at maintaining 55°F, the lower table at maintaining 60°F inside the wine cellar using various fan speeds and under different thermal loads. The thermal loads are derived from assumptions about the size of the cellar; the R-value in the six cellar surfaces (ie walls, floor and ceiling) and the ambient temperature outside the cellar. CellarPro 4200VS wine cooling units are designed to maintain optimal wine storage temperatures in wine cellars up to 1250 cubic feet with adequate insulation, and can be operated with the condenser exposed to conditions up to 115°F.

For more information, click on our 4200VS performance and test data.

The thermal loads above are calculated based on the R-Values shown for all walls and ceiling, and a concrete floor. Lower R-Values in the cellar (eg from glass doors) will increase the thermal load on the wine cellar and will require the cooling unit to operate at higher fan speeds. Warmer climates require higher insulation to enable the cooling unit to operate at lower fan speeds. To be certain that the thermal load won't exceed the capacity of the cooling unit, email your wine cellar specifications to us and we'll be glad to assist you.

Cells shaded blue indicate loads that exceed the capacity of the cooling units shown in this table.