Line Sizing Chart for CellarPro Split Refrigeration Systems
Line Sizing Chart CellarPro Split Refrigeration Systems
Model
|
Liquid Line Size (ODS) up to 100 feet
|
|
Suction Line Size by Length (ODS)
| |
Minimum Suction Line Insulation Thickness (")
|
Up to 25 Feet
| |
Between 25 and 50 Feet
| |
Between 50 and 100 Feet
|
3000S, Sh, Scm
|
1/4
| |
1/2
| |
1/2
| |
1/2
| |
1/2
|
4000S, Sh, Scm, Swc, Shwc
|
3/8
| |
1/2
| |
1/2
| |
1/2
| |
1/2
|
6000S, Scm / AH6500S
|
3/8
| |
1/2
| |
5/8
| |
5/8
| |
1/2
|
8000S, Scm, Swc / AH8500S
|
3/8
| |
5/8
| |
5/8
| |
7/8
| |
5/8
|
AH18S*
|
3/8
| |
3/4
| |
3/4
| |
7/8
| |
5/8
|
AH24S*
|
3/8
| |
3/4
| |
7/8
| |
1-1/8
| |
5/8
|
AH30S*
|
3/8
| |
7/8
| |
7/8
| |
1-1/8
| |
5/8
|
* AH18S-30S optional hot gas bypass line: 1/2" ODS up to 100 feet.
Line lengths are expressed in equivalent feet = actual run length + fitting allowances.
Use only dehydrated refrigeration service tubing and refrigeration-grade fittings.
Install refrigeration tubing in accordance with local codes and ASHRAE guidelines.
|
|
|
|