• Home
  • Cooling Unit Sizing Table 1800XTSr | CellarPro

1800XTSr: Sizing Table - Wine Cellars 100-400 cubic ft

Cooling Unit Output

1800XTSr
55°F:1886 BTUH
60°F: 2031 BTUH
Decibels 50 dBA

Cellar Size

Ambient
Temperature
Thermal Load (BTUH)
55°F Cellar Temp60°F Cellar Temp
R12R19R12R19

100

Cubic Feet

65°F956912841803
75°F1068979940862
85°F118010461038920
95°FXXXX

200

Cubic Feet

65°F1220115710741018
75°F1380125312141103
85°F1538134913531187
95°FXXXX

300

Cubic Feet

65°F1501142213211251
75°F1700154214961357
85°F(1900)166216721463
95°FXXXX

400

Cubic Feet

65°F1698160914941416
75°F(1921)174416901535
85°F(2146)187918881654
95°FXXXX

Cellar Insulation - walls, ceiling, floor. If your cellar is constructed with glass, or has uninsulated walls, or does not have a vapor barrier, the thermal load will be much higher than what's shown in the table. In this case, please visit our Thermal Load Worksheet to request a customized calculation for your cellar.

Cells shaded blue indicate loads that exceed the capacity of the cooling units shown in this table.

Each of our cooling units includes sizing guidelines that are based on R19 insulation throughout the cellar and 85°F peak ambient temperatures outside the cellar. To find the BTUH output for the 1800XTSr cooling unit at 55°F and 60°F, and the thermal loads for various-size cellars, refer to the table. In order to maintain your desired cellar temperature, the cooling unit's BTUH output (at 55°F or 60°F inside the cellar) must be greater than the load of your cellar, as shown in the table.